Gateways
Type
- PROFIBUS AS-i
- Gateway with programming in C Starter Kit
- PROFIBUS AS-i Basic
- PROFIBUS AS-i IP65
- PROFIBUS AS-i IP65 M12
- PROFINET AS-i
- EtherNet/IP + ModbusTCP AS-i
- DeviceNet AS-i
- ControlLogix AS-i
- Compact- / MicroLogix AS-i
- EtherCAT AS-i
- CC-Link AS-i
- CANopen AS-i
- RS 485 Modbus AS-i
- RS 232 AS-i
- Safety, PROFIBUS
- Safety Gateways in Stainless Steel Starter Kit
- Safety, PROFINET
- PROFIsafe, PROFIBUS
- PROFIsafe, PROFINET
- Safety, sercos
- Safety, EtherNet/IP + ModbusTCP
- Safety, EtherCAT
Model
- Gateway
- Gateway with integrated Safety Monitor
Fieldbus interface
- PROFIBUS
- PROFINET
- EtherNet/IP + Modbus/TCP
- DeviceNet
- ControlLogix
- complete set ControlLogix
- CompactLogix, MicrolLogix1500
- complete set CompactLogix, MicrolLogix1500
- EtherCAT
- CC-Link
- CANopen
- Modbus/RTU; RS 485
- RS 232
- sercos
Number of AS-i networks, number of AS-i Master
- 2 AS-i networks, 2 AS-i Masters
- 1 AS-i network, 1 AS-i Master
- 2 AS-i networks, 1 AS-i Master
1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies
- yes, max. 4A/AS-i network
- no, max. 8A/AS-i network, redundant supply
- no, max. 8A/AS-i network
Diagnostic and configuration interface
- Ethernet diagnostic
- RS 232
- Ethernet fieldbus + RS 232
- Ethernet fieldbus + Ethernet diagnostic
Recognition of duplicate AS-i addresses
- yes
- no
AS-i fault detector
- yes
Outputs Safety, SIL 3, cat. 4
- 4 release circuits; 2 x relay, 2 x fast electronic safe outputs
- 2 release circuits; 2 x 2 relay
- 6 release circuits; 6 x fast electronic safe outputs
Additional attributes:
- Protection rating
- Programming in C
- Inputs digital, EDM
- Inputs safety, expandable to
- Safety outputs, independent according to SIL 3, expandable to
- Safety communication
Figure
|
Type
|
Model
|
Protection rating
|
Fieldbus interface
|
Number of AS-i networks, number of AS-i Master
|
1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies
|
Diagnostic and configuration interface
|
Recognition of duplicate AS-i addresses
|
AS-i fault detector
|
Programming in C
|
Inputs digital, EDM
|
Inputs safety, expandable to
|
Outputs Safety, SIL 3, cat. 4
|
Safety outputs, independent according to SIL 3, expandable to
|
Safety communication
|
Article No.
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
Gateway with programming in C Starter Kit
|
Gateway
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network
|
-
|
no
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i
|
Gateway
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
-
|
no
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i Basic
|
Gateway
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
-
|
no
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i IP65
|
Gateway
|
IP65, PROFIBUS via spring-type terminals
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
-
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFIBUS AS-i IP65 M12
|
Gateway
|
IP65, PROFIBUS via M12
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
-
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
PROFINET AS-i
|
Gateway
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
PROFINET AS-i
|
Gateway
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
PROFINET AS-i
|
Gateway
|
IP20
|
PROFINET
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
PROFINET AS-i
|
Gateway
|
IP20
|
PROFINET
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
-
|
no
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
EtherNet/IP + ModbusTCP AS-i
|
Gateway
|
IP20
|
EtherNet/IP + Modbus/TCP
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
EtherNet/IP + ModbusTCP AS-i
|
Gateway
|
IP20
|
EtherNet/IP + Modbus/TCP
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
EtherNet/IP + ModbusTCP AS-i
|
Gateway
|
IP20
|
EtherNet/IP + Modbus/TCP
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
-
|
-
|
-
|
-
|
-
| ||
DeviceNet AS-i
|
Gateway
|
IP20
|
DeviceNet
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
DeviceNet AS-i
|
Gateway
|
IP20
|
DeviceNet
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
DeviceNet AS-i
|
Gateway
|
IP20
|
DeviceNet
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
ControlLogix AS-i
|
Gateway
|
IP20
|
ControlLogix
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
ControlLogix AS-i
|
Gateway
|
IP20
|
complete set ControlLogix
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
Compact- / MicroLogix AS-i
|
Gateway
|
IP20
|
CompactLogix, MicrolLogix1500
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
Compact- / MicroLogix AS-i
|
Gateway
|
IP20
|
complete set CompactLogix, MicrolLogix1500
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
EtherCAT AS-i
|
Gateway
|
IP20
|
EtherCAT
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
EtherCAT AS-i
|
Gateway
|
IP20
|
EtherCAT
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
EtherCAT AS-i
|
Gateway
|
IP20
|
EtherCAT
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
EtherCAT AS-i
|
Gateway
|
IP20
|
EtherCAT
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
CC-Link AS-i
|
Gateway
|
IP20
|
CC-Link
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
-
|
no
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
CANopen AS-i
|
Gateway
|
IP20
|
CANopen
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
CANopen AS-i
|
Gateway
|
IP20
|
CANopen
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
CANopen AS-i
|
Gateway
|
IP20
|
CANopen
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
RS 485 Modbus AS-i
|
Gateway
|
IP20
|
Modbus/RTU; RS 485
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
RS 485 Modbus AS-i
|
Gateway
|
IP20
|
Modbus/RTU; RS 485
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
RS 485 Modbus AS-i
|
Gateway
|
IP20
|
Modbus/RTU; RS 485
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
RS 232 AS-i
|
Gateway
|
IP20
|
RS 232
|
1 AS-i network, 1 AS-i Master
|
no, max. 8A/AS-i network
|
-
|
no
|
yes
|
no
|
-
|
-
|
-
|
-
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels, max. 1922 in max. configuration
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 32, max. 992 in max. configuration
|
Safe Link
| ||
Safety Gateways in Stainless Steel Starter Kit
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels, max. 1922 in max. configuration
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 32, max. 992 in max. configuration
|
Safe Link
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
2 release circuits; 2 x 2 relay
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 1 AS-i Master
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 1 AS-i Master
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
2 release circuits; 2 x 2 relay
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
2 release circuits; 2 x 2 relay
|
max. 16
|
-
| ||
Safety, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
6
|
max. 31 x 2 channels, max. 1891 in max. configuration
|
6 release circuits; 6 x fast electronic safe outputs
|
max. 31, max. 991 in max. configuration
|
Safe Link
| ||
Safety, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels, max. 1922 in max. configuration
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 32, max. 992 in max. configuration
|
Safe Link
| ||
Safety, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
2 AS-i networks, 1 AS-i Master
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
1 AS-i network, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + Ethernet diagnostic
|
yes
|
yes
|
optional
|
6
|
max. 31 x 2 channels, max. 1891 in max. configuration
|
6 release circuits; 6 x fast electronic safe outputs
|
max. 31, max. 991 in max. configuration
|
Safe Link
| ||
PROFIsafe, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
PROFIsafe (F-CPU) + ASIMON 256 Devices
| ||
PROFIsafe, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
PROFIsafe (F-CPU) + ASIMON 256 Devices
| ||
PROFIsafe, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
PROFIsafe (F-CPU)
| ||
PROFIsafe, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
PROFIsafe (F-CPU)
| ||
PROFIsafe, PROFIBUS
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFIBUS
|
1 AS-i network, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
-
|
max. 31 x 2 channels
|
-
|
max. 16
|
PROFIsafe (F-CPU)
| ||
PROFIsafe, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
PROFIsafe (F-CPU) + ASIMON 256 Devices
| ||
PROFIsafe, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
PROFIsafe (F-CPU)
| ||
PROFIsafe, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
PROFIsafe (F-CPU)
| ||
PROFIsafe, PROFINET
|
Gateway with integrated Safety Monitor
|
IP20
|
PROFINET
|
1 AS-i network, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + Ethernet diagnostic
|
yes
|
yes
|
optional
|
6
|
max. 31 x 2 channels
|
6 release circuits; 6 x fast electronic safe outputs
|
max. 31
|
PROFIsafe (F-CPU) + ASIMON 256 Devices
| ||
Safety, sercos
|
Gateway with integrated Safety Monitor
|
IP20
|
sercos
|
2 AS-i networks, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels, max. 1922 in max. configuration
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 32, max. 992 in max. configuration
|
Safe Link
| ||
Safety, EtherNet/IP + ModbusTCP
|
Gateway with integrated Safety Monitor
|
IP20
|
EtherNet/IP + Modbus/TCP
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + Ethernet diagnostic
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels, max. 1922 in max. configuration
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 32, max. 992 in max. configuration
|
Safe Link
| ||
Safety, EtherNet/IP + ModbusTCP
|
Gateway with integrated Safety Monitor
|
IP20
|
EtherNet/IP + Modbus/TCP
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, EtherNet/IP + ModbusTCP
|
Gateway with integrated Safety Monitor
|
IP20
|
EtherNet/IP + Modbus/TCP
|
2 AS-i networks, 2 AS-i Masters
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, EtherNet/IP + ModbusTCP
|
Gateway with integrated Safety Monitor
|
IP20
|
EtherNet/IP + Modbus/TCP
|
2 AS-i networks, 1 AS-i Master
|
no, max. 8A/AS-i network, redundant supply
|
Ethernet fieldbus + RS 232
|
yes
|
yes
|
optional
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, EtherCAT
|
Gateway with integrated Safety Monitor
|
IP20
|
EtherCAT
|
2 AS-i networks, 2 AS-i Masters
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, EtherCAT
|
Gateway with integrated Safety Monitor
|
IP20
|
EtherCAT
|
2 AS-i networks, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
RS 232
|
yes
|
yes
|
no
|
4
|
max. 62 x 2 channels
|
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
|
max. 16
|
-
| ||
Safety, EtherCAT
|
Gateway with integrated Safety Monitor
|
IP20
|
EtherCAT
|
1 AS-i network, 1 AS-i Master
|
yes, max. 4A/AS-i network
|
Ethernet diagnostic
|
yes
|
yes
|
optional
|
6
|
max. 31 x 2 channels, max. 1891 in max. configuration
|
6 release circuits; 6 x fast electronic safe outputs
|
max. 31, max. 991 in max. configuration
|
Safe Link
|