74 of 74 products selected

Type

  • PROFIBUS AS-i
  • Gateway with programming in C Starter Kit
  • PROFIBUS AS-i Basic
  • PROFIBUS AS-i IP65
  • PROFIBUS AS-i IP65 M12
  • PROFINET AS-i
  • EtherNet/IP + ModbusTCP AS-i
  • DeviceNet AS-i
  • ControlLogix AS-i
  • Compact- / MicroLogix AS-i
  • EtherCAT AS-i
  • CC-Link AS-i
  • CANopen AS-i
  • RS 485 Modbus AS-i
  • RS 232 AS-i
  • Safety, PROFIBUS
  • Safety Gateways in Stainless Steel Starter Kit
  • Safety, PROFINET
  • PROFIsafe, PROFIBUS
  • PROFIsafe, PROFINET
  • Safety, sercos
  • Safety, EtherNet/IP + ModbusTCP
  • Safety, EtherCAT

Model

  • Gateway
  • Gateway with integrated Safety Monitor

Field­bus in­ter­face

  • PROFIBUS
  • PROFINET
  • EtherNet/IP + Modbus/TCP
  • DeviceNet
  • ControlLogix
  • complete set ControlLogix
  • CompactLogix, MicrolLogix1500
  • complete set CompactLogix, MicrolLogix1500
  • EtherCAT
  • CC-Link
  • CANopen
  • Modbus/RTU; RS 485
  • RS 232
  • sercos

Num­ber of AS-i net­works, num­ber of AS-i Master

  • 2 AS-i networks, 2 AS-i Masters
  • 1 AS-i network, 1 AS-i Master
  • 2 AS-i networks, 1 AS-i Master

1 power sup­ply, 1 gate­way for 2 AS-i net­works, in­ex­pen­sive power sup­plies

  • yes, max. 4A/AS-i network
  • no, max. 8A/AS-i network, redundant supply
  • no, max. 8A/AS-i network

Di­ag­nos­tic and con­fig­u­ra­tion in­ter­face

  • Ethernet diagnostic
  • RS 232
  • Ethernet fieldbus + RS 232
  • Ethernet fieldbus + Ethernet diagnostic

Recog­ni­tion of du­pli­cate AS-i ad­dresses

  • yes
  • no

AS-i fault de­tec­tor

  • yes

Out­puts Safety, SIL 3, cat. 4

  • 4 release circuits; 2 x relay, 2 x fast electronic safe outputs
  • 2 release circuits; 2 x 2 relay
  • 6 release circuits; 6 x fast electronic safe outputs

Additional attributes:

  • Protection rating
  • Programming in C
  • Inputs digital, EDM
  • Inputs safety, expandable to
  • Safety outputs, independent according to SIL 3, expandable to
  • Safety communication
Fig­ure
Type
Model
Pro­tec­tion rat­ing
Field­bus in­ter­face
Num­ber of AS-i net­works, num­ber of AS-i Master
1 power sup­ply, 1 gate­way for 2 AS-i net­works, in­ex­pen­sive power sup­plies
Di­ag­nos­tic and con­fig­u­ra­tion in­ter­face
Recog­ni­tion of du­pli­cate AS-i ad­dresses
AS-i fault de­tec­tor
Pro­gram­ming in C
In­puts dig­i­tal, EDM
In­puts safety, ex­pand­able to
Out­puts Safety, SIL 3, cat. 4
Safety out­puts, in­de­pen­dent ac­cord­ing to SIL 3, ex­pand­able to
Safety com­mu­ni­ca­tion
Ar­ti­cle No.
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
Gateway with programming in C Starter Kit
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network
-
no
yes
no
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
-
no
yes
no
-
-
-
-
-
PROFIBUS AS-i Basic
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
-
no
yes
no
-
-
-
-
-
PROFIBUS AS-i IP65
Gateway
IP65, PROFIBUS via spring-type terminals
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
-
yes
yes
no
-
-
-
-
-
PROFIBUS AS-i IP65 M12
Gateway
IP65, PROFIBUS via M12
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
-
yes
yes
no
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
-
no
yes
no
-
-
-
-
-
EtherNet/IP + ModbusTCP AS-i
Gateway
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
EtherNet/IP + ModbusTCP AS-i
Gateway
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
EtherNet/IP + ModbusTCP AS-i
Gateway
IP20
EtherNet/IP + Modbus/TCP
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
DeviceNet AS-i
Gateway
IP20
DeviceNet
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
DeviceNet AS-i
Gateway
IP20
DeviceNet
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
DeviceNet AS-i
Gateway
IP20
DeviceNet
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
ControlLogix AS-i
Gateway
IP20
ControlLogix
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
ControlLogix AS-i
Gateway
IP20
complete set ControlLogix
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
Compact- / MicroLogix AS-i
Gateway
IP20
CompactLogix, MicrolLogix1500
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
Compact- / MicroLogix AS-i
Gateway
IP20
complete set CompactLogix, MicrolLogix1500
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
EtherCAT AS-i
Gateway
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
no
-
-
-
-
-
EtherCAT AS-i
Gateway
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
EtherCAT AS-i
Gateway
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
EtherCAT AS-i
Gateway
IP20
EtherCAT
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
CC-Link AS-i
Gateway
IP20
CC-Link
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
-
no
yes
no
-
-
-
-
-
CANopen AS-i
Gateway
IP20
CANopen
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
CANopen AS-i
Gateway
IP20
CANopen
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
CANopen AS-i
Gateway
IP20
CANopen
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
RS 485 Modbus AS-i
Gateway
IP20
Modbus/RTU; RS 485
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
RS 485 Modbus AS-i
Gateway
IP20
Modbus/RTU; RS 485
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
RS 485 Modbus AS-i
Gateway
IP20
Modbus/RTU; RS 485
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
RS 232 AS-i
Gateway
IP20
RS 232
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
-
no
yes
no
-
-
-
-
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety Gateways in Stainless Steel Starter Kit
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
no
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
-
max. 31 x 2 channels
-
max. 16
PROFIsafe (F-CPU)
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
max. 31 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 31
PROFIsafe (F-CPU) + ASIMON 256 Devices
Safety, sercos
Gateway with integrated Safety Monitor
IP20
sercos
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
EtherCAT
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
EtherCAT
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link