47 of 47 products selected

Type

  • Safety Basic Monitor
  • Safety Basic Monitor Starter Kit
  • Safety, PROFIBUS
  • Safety Gateways in Stainless Steel Starter Kit
  • Safety, PROFINET
  • PROFIsafe, PROFIBUS
  • PROFIsafe, PROFINET
  • Safety, sercos
  • Safety, EtherNet/IP + ModbusTCP
  • Safety, EtherCAT
  • Safety Monitor in Stainless Steel
  • Consortial Safety Monitor

Model

  • Safety Basic Monitor
  • Safety Basic Monitor with extended features
  • Gateway with integrated Safety Monitor
  • Safety Monitor in Stainless Steel
  • Consortial Safety Monitor

In­puts Safety, SIL 3, Cat. 4

  • 4 x 2 channels, inputs 3+4 optional for standstill monitor
  • 4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
  • 4 x 2 channels
  • 3 x 2 channels

In­puts safety, ex­pand­able to

  • max. 31 x 2 channels
  • max. 62 x 2 channels, max. 1922 in max. configuration
  • max. 31 x 2 channels, max. 1891 in max. configuration
  • max. 62 x 2 channels

Out­puts Safety, SIL 3, cat. 4

  • 2 release circuits; 2 x fast electronic safe output
  • 6 release circuits; 6 x fast electronic safe outputs
  • 4 release circuits; 2 x relay, 2 x fast electronic safe outputs
  • 2 release circuits; 2 x 2 relay
  • 2 release circuits; 2 x relay
  • 1 release circuit; 1 x 2 relay

Safety out­puts, in­de­pen­dent ac­cord­ing to SIL 3, ex­pand­able to

  • max. 8
  • max. 32, max. 992 in max. configuration
  • max. 31, max. 991 in max. configuration
  • max. 16
  • max. 31

Safety com­mu­ni­ca­tion

  • Safe Link
  • PROFIsafe (F-CPU) + ASIMON 256 Devices
  • PROFIsafe (F-CPU)

1 power sup­ply, 1 gate­way for 2 AS-i net­works, in­ex­pen­sive power sup­plies 

  • yes, max. 0,5A/AS-i network, max. 8A with AS-i power supply
  • no, max. 8A/AS-i network
  • yes, max. 4A/AS-i network
  • no, max. 8A/AS-i network, redundant supply

Di­ag­nos­tic and con­fig­u­ra­tion in­ter­face 

  • USB
  • Ethernet diagnostic
  • RS 232
  • Ethernet fieldbus + Ethernet diagnostic
  • Ethernet fieldbus + RS 232

Additional attributes:

  • Protection rating
  • Inputs digital, EDM
  • Fieldbus interface
  • Number of AS-i networks, number of AS-i Master
  • Recognition of duplicate AS-i addresses
  • AS-i fault detector
  • Programming in C
Fig­ure
Type
Model
Pro­tec­tion rat­ing
In­puts Safety, SIL 3, Cat. 4
In­puts dig­i­tal, EDM
In­puts safety, ex­pand­able to
Out­puts Safety, SIL 3, cat. 4
Safety out­puts, in­de­pen­dent ac­cord­ing to SIL 3, ex­pand­able to
Safety com­mu­ni­ca­tion
Field­bus in­ter­face
Num­ber of AS-i net­works, num­ber of AS-i Master
1 power sup­ply, 1 gate­way for 2 AS-i net­works, in­ex­pen­sive power sup­plies
Di­ag­nos­tic and con­fig­u­ra­tion in­ter­face
Recog­ni­tion of du­pli­cate AS-i ad­dresses
AS-i fault de­tec­tor
Pro­gram­ming in C
Ar­ti­cle No.
Safety Basic Monitor
Safety Basic Monitor
IP20
4 x 2 channels, inputs 3+4 optional for standstill monitor
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe output
max. 8
-
Signaling contacts
1 AS-i network, 1 AS-i Master
yes, max. 0,5A/AS-i network, max. 8A with AS-i power supply
USB
no
no
no
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
4 x 2 channels, inputs 3+4 optional for standstill monitor
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe output
max. 8
-
AS-i monitors
1 AS-i network, 1 AS-i Master
no, max. 8A/AS-i network
USB
no
no
no
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
4 x 2 channels, inputs 3+4 optional for standstill monitor
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe output
max. 8
-
Signaling contacts
1 AS-i network, 1 AS-i Master
yes, max. 0,5A/AS-i network, max. 8A with AS-i power supply
USB
no
no
no
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe output
max. 8
-
Signaling contacts
1 AS-i network, 1 AS-i Master
yes, max. 0,5A/AS-i network, max. 8A with AS-i power supply
USB
no
no
no
Safety Basic Monitor Starter Kit
Safety Basic Monitor with extended features
IP20
4 x 2 channels
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe output
max. 8
-
Signaling contacts
1 AS-i network, 1 AS-i Master
yes, max. 0,5A/AS-i network, max. 8A with AS-i power supply
USB
no
no
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety Gateways in Stainless Steel Starter Kit
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
no
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
no
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFINET
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
no
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
-
max. 31 x 2 channels
-
max. 16
PROFIsafe (F-CPU)
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 31
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
-
max. 16
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON 256 Devices
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
no
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU)
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
no
Safety, sercos
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
sercos
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
EtherNet/IP + Modbus/TCP
2 AS-i networks, 1 AS-i Master
no, max. 8A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
EtherCAT
1 AS-i network, 1 AS-i Master
yes, max. 4A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4A/AS-i network
RS 232
yes
yes
no
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
EtherCAT
2 AS-i networks, 1 AS-i Master
yes, max. 4A/AS-i network
RS 232
yes
yes
no
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
IP20
-
4
max. 62 x 2 channels
2 release circuits; 2 x relay
max. 16
-
AS-i Safety Monitors
2 AS-i networks, no AS-i Master, AS-i Monitor
no, max. 8A/AS-i network, redundant supply
Ethernet diagnostic
yes
yes
no
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
AS-i Safety Monitors
2 AS-i networks, no AS-i Master, AS-i Monitor
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
IP20
-
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
AS-i Safety Monitors
2 AS-i networks, no AS-i Master, AS-i Monitor
no, max. 8A/AS-i network, redundant supply
RS 232
yes
yes
no
Consortial Safety Monitor
Consortial Safety Monitor
IP20
-
2
max. 31 x 2 channels
2 release circuits; 2 x 2 relay
-
-
AS-i monitors
1 AS-i network, no AS-i Master, AS-i Monitor
no, max. 8A/AS-i network
RS 232
no
no
no
Consortial Safety Monitor
Consortial Safety Monitor
IP20
-
2
max. 31 x 2 channels
1 release circuit; 1 x 2 relay
-
-
AS-i monitors
1 AS-i network, no AS-i Master, AS-i Monitor
no, max. 8A/AS-i network
RS 232
no
no
no