Thứ Sáu, 13 tháng 7, 2012

Bihl-Wiedemann Vietnam Distributor-BWU1939

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7

Safety I/O Modules

28 of 28 products selected

Type

  • IP20, 22,5 mm x 50 mm, 3 x COMBICON, Safety
  • IP20, 22,5 mm x 50 mm, 4 x COMBICON
  • IP20, 22,5 mm x 114 mm, 4 x COMBICON, Safety
  • IP20, 22,5 mm x 114 mm, 6 x COMBICON, Safety
  • IP67, 4 x M12, Safety
  • circuit board 43mm x 30mm
  • circuit board 73mm x 37,5mm

In­puts Safety, SIL 3, Cat. 4

  • 1 x 2 channels
  • 1 x 2 channels; SIL 2, Cat. 3
  • 2 x 2 channels
  • 4 x 2 channels
  • 8 x 2 channels

In­puts dig­i­tal, EDM 

  • 4
  • 1 EDM
  • 1 EDM + 3 standard
  • 2

Out­puts Safety, SIL 3, cat. 4

  • 1 release circuit; 2 x 2 relay
  • 1 release circuit; 2 x fast electronic safe outputs
  • 2 release circuit; 2 x fast electronic safe outputs
  • 1 release circuit; 1 x fast electronic safe output

Out­puts dig­i­tal

  • 2 x electronic
  • 4 x electronic

Safety sig­nal in­puts

  • floating contacts
  • safety mats 1.2 kΩ or 8.2 kΩ monitoring resistor
  • optoelectronic protective devices
  • floating contacts, optoelectronic protective devices
  • complementary switch

Out­put volt­age (ac­tu­a­tor sup­ply) 

  • out of AUX
  • out of AS-i

AS-i con­nec­tion 

  • clamps
  • AS-i using profile cable, sensors using M12
  • AS-i and sensors using M12
  • connecting wires

Additional attributes:

  • Housing
  • Protection rating
  • Coated
  • AS-i address
  • Special function
Fig­ure
Type
Hous­ing
Pro­tec­tion rat­ing
In­puts Safety, SIL 3, Cat. 4
In­puts dig­i­tal, EDM
Out­puts Safety, SIL 3, cat. 4
Out­puts dig­i­tal
Safety sig­nal in­puts
Out­put volt­age (ac­tu­a­tor sup­ply)
AS-i con­nec­tion
AS-i ad­dress
Coated
Spe­cial func­tion
Ar­ti­cle No.
IP20, 22,5 mm x 50 mm, 3 x COMBICON, Safety
3 x COMBICON
IP20
1 x 2 channels
-
-
2 x electronic
floating contacts
out of AUX
clamps
1 Single Slave
-
-
IP20, 22,5 mm x 50 mm, 3 x COMBICON, Safety
3 x COMBICON
IP20
1 x 2 channels
-
-
2 x electronic
floating contacts
out of AS-i
clamps
1 Single Slave
-
-
IP20, 22,5 mm x 50 mm, 3 x COMBICON, Safety
3 x COMBICON
IP20
1 x 2 channels; SIL 2, Cat. 3
-
-
2 x electronic
safety mats 1.2 kΩ or 8.2 kΩ monitoring resistor
out of AUX
clamps
1 Single Slave
-
-
IP20, 22,5 mm x 50 mm, 3 x COMBICON, Safety
3 x COMBICON
IP20
1 x 2 channels
-
-
2 x electronic
optoelectronic protective devices
out of AUX
clamps
1 Single Slave
-
-
IP20, 22,5 mm x 50 mm, 4 x COMBICON
4 x COMBICON
IP20
-
4
-
4 x electronic
-
out of AS-i
clamps
1 AB Slave
-
-
IP20, 22,5 mm x 114 mm, 4 x COMBICON, Safety
4 x COMBICON
IP20
2 x 2 channels
-
-
4 x electronic
floating contacts
out of AUX
clamps
2 Single Slaves
-
-
IP20, 22,5 mm x 114 mm, 4 x COMBICON, Safety
4 x COMBICON
IP20
-
1 EDM
1 release circuit; 2 x 2 relay
-
-
-
clamps
1 Single Slave + 1 AB Slave
-
-
IP20, 22,5 mm x 114 mm, 4 x COMBICON, Safety
4 x COMBICON
IP20
1 x 2 channels
1 EDM
1 release circuit; 2 x 2 relay
-
floating contacts
-
clamps
2 Single Slaves + 1 AB Slave
-
-
IP20, 22,5 mm x 114 mm, 4 x COMBICON, Safety
4 x COMBICON
IP20
-
1 EDM + 3 standard
1 release circuit; 2 x fast electronic safe outputs
-
-
-
clamps
1 Single Slave + 2 AB Slaves
-
-
IP20, 22,5 mm x 114 mm, 6 x COMBICON, Safety
6 x COMBICON
IP20
4 x 2 channels
-
2 release circuit; 2 x fast electronic safe outputs
-
floating contacts, optoelectronic protective devices
-
clamps
depending on number of Safety I/Os
-
-
IP20, 22,5 mm x 114 mm, 6 x COMBICON, Safety
6 x COMBICON
IP20
8 x 2 channels
-
1 release circuit; 1 x fast electronic safe output
-
floating contacts, optoelectronic protective devices
-
clamps
depending on number of Safety I/Os
-
-
IP67, 4 x M12, Safety
4 x M12
IP67
2 x 2 channels
-
-
-
floating contacts
-
AS-i using profile cable, sensors using M12
2 Single Slaves
-
-
IP67, 4 x M12, Safety
4 x M12
IP67
1 x 2 channels
-
-
2 x electronic
floating contacts
-
AS-i using profile cable, sensors using M12
1 Single Slave
-
-
IP67, 4 x M12, Safety
4 x M12
IP67
1 x 2 channels
-
-
2 x electronic
optoelectronic protective devices
-
AS-i using profile cable, sensors using M12
1 Single Slave
-
-
IP67, 4 x M12, Safety
4 x M12
IP67
1 x 2 channels
-
-
2 x electronic
optoelectronic protective devices
-
AS-i using profile cable, sensors using M12
1 Single Slave
-
Reset output for optoelectronic protective devices
IP67, 4 x M12, Safety
4 x M12
IP67
1 x 2 channels
-
-
2 x electronic
complementary switch
-
AS-i using profile cable, sensors using M12
1 Single Slave
-
-
IP67, 4 x M12, Safety
4 x M12
IP67
1 x 2 channels
-
-
2 x electronic
optoelectronic protective devices
-
AS-i and sensors using M12
1 Single Slave
-
-
IP67, 4 x M12, Safety
4 x M12
IP67
1 x 2 channels
-
-
2 x electronic
floating contacts
-
AS-i and sensors using M12
1 Single Slave
-
-
circuit board 43mm x 30mm
-
-
1 x 2 channels
-
-
2 x electronic
floating contacts
-
-
1 Single Slave
yes
-
circuit board 43mm x 30mm
-
-
1 x 2 channels
-
-
2 x electronic
floating contacts
-
-
1 Single Slave
yes
-
circuit board 43mm x 30mm
-
-
-
2
-
2 x electronic
-
-
-
1 AB Slave
yes
-
circuit board 43mm x 30mm
-
-
-
2
-
2 x electronic
-
-
-
1 AB Slave
yes
-
circuit board 73mm x 37,5mm
-
-
1 x 2 channels
-
-
2 x electronic
floating contacts
-
-
1 Single Slave
no
-
circuit board 73mm x 37,5mm
-
-
1 x 2 channels
-
-
2 x electronic
floating contacts
-
-
1 Single Slave
no
-
circuit board 73mm x 37,5mm
-
-
1 x 2 channels
-
-
2 x electronic
floating contacts
-
-
1 Single Slave
no
-
circuit board 73mm x 37,5mm
-
-
1 x 2 channels
-
-
2 x electronic
floating contacts
-
-
1 Single Slave
no
-
circuit board 73mm x 37,5mm
-
-
-
4
-
4 x electronic
-
out of AS-i
connecting wires
1 AB Slave
yes
-
circuit board 73mm x 37,5mm
-
-
-
4
-
4 x electronic
-
out of AS-i
connecting wires
1 Single Slave
yes
-